PS-ZK03 Transformer Short Circuit Impedance Tester

The short-circuit impedance is an important parameter of the transformer, and the short-circuit impedance method is the traditional method for judging winding deformation. According to GB1094.5-2003 and IEC60076-5:2000, the variation of short-circuit reactance is the only criterion for judging whether the transformer winding is deformed. The low-voltage short-circuit impedance test is the most direct method to check whether the winding is deformed after the transformer is impacted by short-circuit current during operation, or after the transformer is impacted by mechanical force during transportation and installation. It is important for judging whether the transformer can be put into operation. It is also one of the basis for judging whether the transformer requires disassembly inspection.
DOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction

 

  1. 1. Measurement of three-phase short-circuit impedance:
    Display three-phase voltage, three-phase current, three-phase power; automatically calculate the percentage of impedance voltage converted to rated temperature and rated current of the transformer, and the percentage of error with the impedance of the nameplate.
    2. Measurement of single-phase short-circuit impedance:
    Measure the short-circuit impedance of a single-phase transformer.
    3. Measurement of zero-sequence impedance:
    The measurement of zero-sequence impedance is suitable for transformers with neutral point in star connection on the high voltage side.
    4. It can be directly measured within the allowable measurement range of the instrument, and external voltage and current transformers can be connected outside the measurement range. The instrument can set the transformation ratio of the external voltage and current transformers, and directly display the applied voltage and current values.
    5. The instrument adopts large-screen color high-resolution touch LCD, Chinese menu, Chinese prompts, and easy operation.
    6. The instrument comes with a printer, which can print and display data.
    7. Built-in non-power-down memory, can store 200 sets of measurement data.
    8. The instrument is equipped with a U disk interface for accessing test data.
    9. Permanent calendar, clock function, time calibration can be carried out.
    10. The instrument has a wide measurement range, high precision and good stability; small size and light weight are convenient for measurement.

 

Product Parameter 

 

Voltage (range automatic)

15 ~ 400V

± (reading × 0.2% + 3 digits)± 0.04% (range)

Current (range automatic)

0.10 ~ 20A

± (reading × 0.2% + 3 digits) ± 0.04% (range)

Power

COSΦ>0.15

± (reading × 0.5% + 3 digits)

Frequency (power frequency)

45~65(Hz)

Measurement accuracy

±0.1%

Short circuit impedance

0~100%

Measurement accuracy

±0.5%

Repeat stability

ratio difference <0.2%, angular difference <0.02°

Instrument display

5 digits

Instrument protection current

The test current is greater than 18A, the internal relay of the instrument is disconnected, and the overcurrent protection is provided.

Ambient temperature

-10℃~40℃

Relative humidity

≤85%RH

Working power

AC 220V±10% 50Hz±1Hz

Dimensions

Host

360*290*170(mm)

Wire box

360*290*170(mm)

Weight

Host

4.85Kg

Wire box

5.15KG

 

Video

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Differences between open cup flash point tester and closed cup flash point tester
    Differences between open cup flash point tester and closed cup flash point tester
    Flash point is the lowest temperature at which the test flame causes the sample vapor to ignite and the flame to spread to the surface of the liquid under the specified test conditions. The burning point is the temperature at which the sample is heated up and can burn continuously for at least 5 seconds on the basis of the flash point. The flash point and the burning point are used to indicate whether there are highly volatile or flammable substances in relatively non-volatile or flammable substances. They are one of the important parameters for the transportation, storage, operation and safety management of petroleum products.
    Detail
  • The Reliable Load Tap Changer
    The Reliable Load Tap Changer
    When it comes to enhancing the efficiency and performance of transformers, a load tap changer transformer is essential.
    Detail
  • The Essential Guide to Hipot Testers
    The Essential Guide to Hipot Testers
    When it comes to ensuring electrical safety and compliance, a reliable hipot tester is indispensable.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.