PUSH electric Manual oil cup cleaning type insulating oil dielectric loss and volume resistivity tester
PUSH electric Manual oil cup cleaning type insulating oil dielectric loss and volume resistivity tester
PS-2000A Insulating oil dielectric loss tester /Oil tan delta tester is new generation of fully automatic portable insulating oil dielectric loss and resistivity meter designed according to ASTM D924 and GB/5654.7-inch color touch screen It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. It is easy to operate with reliable and accurate test data.
Model No.: PS-2000A
CONTACT NOWDOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction
High automation, heating, measuring dielectric loss, and measuring resistivity can be completed at a time.
The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.
The instrument uses medium frequency induction heating, PID temperature control algorithm. This heating mode has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error.
Using advanced DSP and FFT technology to ensure the stability, accuracy and reliability of the data
Internal standard capacitor for the SF6 charging three pole capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.
Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.
With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.
With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.
Automatic storage measurement data, can store 100 sets of measurement data.
Correction function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.
Automatic emptying cup without disassembly, convenient and quick.
Product Parameters
Parameter
Index
Parameter
Index
measure Range
Capacitance
5pF~200pF
Resolving power
Capacitance
0.01pF
Dielectric loss
0.00001~100
Dielectric loss
10-5
Resistivity
2.5MΩm~20TΩm
Resistivity
0.001M
Measure accuracy
Capacitance
0.5%+1PF
Control accuracy
±0.5℃
Dielectric loss
±(1%Reading+0.0001)
Temperature range
0~125℃
Resistivity
±10%Reading
AC voltage
AC 0~2200V
DC voltage
DC 0~600V
Ambient temperature
0~40℃
Ambient humidity
<80%RH
Working power supply
AC220V±10%(50±1)Hz
Size
420mm*380mm*420mm
Power
100 W
Weight
21Kg(Free cup)
Video
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.
Differences between open cup flash point tester and closed cup flash point tester
Flash point is the lowest temperature at which the test flame causes the sample vapor to ignite and the flame to spread to the surface of the liquid under the specified test conditions. The burning point is the temperature at which the sample is heated up and can burn continuously for at least 5 seconds on the basis of the flash point. The flash point and the burning point are used to indicate whether there are highly volatile or flammable substances in relatively non-volatile or flammable substances. They are one of the important parameters for the transportation, storage, operation and safety management of petroleum products.